Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 112
Filtrar
1.
Lancet Rheumatol ; 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38574745

RESUMO

Giant cell arteritis is the principal form of systemic vasculitis affecting people over 50. Large-vessel involvement, termed large vessel giant cell arteritis, mainly affects the aorta and its branches, often occurring alongside cranial giant cell arteritis, but large vessel giant cell arteritis without cranial giant cell arteritis can also occur. Patients mostly present with constitutional symptoms, with localising large vessel giant cell arteritis symptoms present in a minority of patients only. Large vessel giant cell arteritis is usually overlooked until clinicians seek to exclude it with imaging by ultrasonography, magnetic resonance angiography (MRA), computed tomography angiography (CTA), or [18F]fluorodeoxyglucose-PET-CT. Although the role of imaging in treatment monitoring remains uncertain, imaging by MRA or CTA is crucial for identifying aortic aneurysm formation during patient follow up. In this Series paper, we define the large vessel subset of giant cell arteritis and summarise its clinical challenges. Furthermore, we identify areas for future research regarding the management of large vessel giant cell arteritis.

2.
Sci Rep ; 14(1): 4724, 2024 02 27.
Artigo em Inglês | MEDLINE | ID: mdl-38413684

RESUMO

Photon-counting detector (PCD)-CT allows for reconstruction of virtual non-iodine (VNI) images from contrast-enhanced datasets. This study assesses the diagnostic performance of aortic valve calcification scoring (AVCS) derived from VNI datasets generated with a 1st generation clinical dual-source PCD-CT. AVCS was evaluated in 123 patients (statistical analysis only comprising patients with aortic valve calcifications [n = 56; 63.2 ± 11.6 years]), who underwent contrast enhanced electrocardiogram-gated (either prospective or retrospective or both) cardiac CT on a clinical PCD system. Patient data was reconstructed at 70 keV employing a VNI reconstruction algorithm. True non-contrast (TNC) scans at 70 keV without quantum iterative reconstruction served as reference in all individuals. Subgroup analysis was performed in 17 patients who received both, prospectively and retrospectively gated contrast enhanced scans (n = 8 with aortic valve calcifications). VNI images with prospective/retrospective gating had an overall sensitivity of 69.2%/56.0%, specificity of 100%/100%, accuracy of 85.4%/81.0%, positive predictive value of 100%/100%, and a negative predictive value of 78.2%/75.0%. VNI images with retrospective gating achieved similar results. For both gating approaches, AVCSVNI showed high correlation (r = 0.983, P < 0.001 for prospective; r = 0.986, P < 0.001 for retrospective) with AVCSTNC. Subgroup analyses demonstrated excellent intra-individual correlation between different acquisition modes (r = 0.986, P < 0.001). Thus, VNI images derived from cardiac PCD-CT allow for excellent diagnostic performance in the assessment of AVCS, suggesting potential for the omission of true non-contrast scans in the clinical workup of patients with aortic calcifications.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Valva Aórtica/patologia , Calcinose , Iodo , Humanos , Estudos Retrospectivos , Valva Aórtica/diagnóstico por imagem , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos , Angiografia
3.
Artigo em Inglês | MEDLINE | ID: mdl-38305463

RESUMO

OBJECTIVES: Our aim was to introduce a standardized system for assessing the extent of giant cell arteritis (GCA) on MRI, titled MRVAS (MR Vasculitis Activity score). To obtain a comprehensive view, we used an extensive MRI protocol including cranial vessels and the aorta with its branches. To test reliability, MRI was assessed by 4 readers with different levels of experience. METHODS: 80 patients with suspected GCA underwent MRI of cranial arteries and the aorta/branches (20 vessel segments). Every vessel was rated dichotomous [inflamed (coded as 1) or not 0], providing a summed score from 0 to 20. Blinded readers (two experienced radiologists [ExR], two inexperienced radiologists [InR]) applied the MRVAS on an individual vessel and an overall level (defined as the highest score of any of the individual vessel scores). To determine interrater agreement, Cohen's kappa was calculated for pairwise comparison of each reader for individual vessel segments. Intraclass correlation coefficients (ICC) were used for the MRVAS score. RESULTS: Concordance rates were excellent for both sub-cohorts on an individual vessel-based (GCA, ICC, 0.95; and non-GCA, ICC, 0.96) and Overall MRVAS score level (GCA, ICC, 0.96; and non-GCA, ICC, 1.0). Interrater agreement yielded significant concordance (p< 0.001) for all pairs (kappa range 0.78-0.98). No significant differences between ERs and IRs were observed (p= 0.38). CONCLUSION: The proposed MRVAS score allows standardized scoring of inflammation in GCA and achieved high agreement rates in a prospective setting.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38197587

RESUMO

OBJECTIVE: Giant Cell arteritis (GCA) is a large vessel vasculitis, typically involving the aorta and its branches with predilection for the scalp arteries. Intracranial involvement is still part of ongoing research. We assess inflammation of the intracranial arteries on 3D-black-blood magnetic resonance imaging (3D-CS-BB-MRI) in patients with GCA and age-matched controls. METHODS: 105 patients with 3D-CS-BB-MRI of the brain were included in this retrospective dual-center case-control study; 55 with diagnosed GCA and 50 age-matched controls. High-resolution 3D-CS-BB-MRI was performed on a 3 Tesla MR scanner with a post-contrast 3D-compressed-sensing (CS) MR pulse sequence, specifically a T1-weighted sampling perfection, application-optimized contrasts using different flip angle evolution (SPACE) pulse sequence with whole-brain coverage and isotropic resolution of 0.55 mm3. Two neuroradiologists blinded to clinical data independently scored the cerebral arteries qualitatively for inflammation; circumferential vessel wall thickening and contrast enhancement were scored positive for vasculitis. RESULTS: 8 of 55 GCA patients (14.5%) showed inflammation of at least one intracranial artery. The internal carotid artery (ICA) was affected in 6/55 (10.9%), the vertebral artery in 4/55 (7.3%) and the basilar artery and posterior cerebral artery in 1/55 (1.8%). All patients with inflammatory changes reported headaches and none showed any focal neurological deficit. Besides headache and general weakness, there was no significant correlation between inflammation of the intracranial arteries and clinical symptoms. No age-matched control patient showed inflammatory changes of the intracranial arteries. CONCLUSION: High-resolution 3D-CS-BB-MRI revealed inflammatory changes of intracranial arteries in 14.5% of GCA patients with the intradural ICA as the most frequently affected vessel.

5.
AJR Am J Roentgenol ; 222(2): e2330154, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-37966036

RESUMO

BACKGROUND. Dual-energy CT pulmonary angiography (CTPA) with energy-integrating detector (EID) technology is limited by the inability to use high-pitch technique. OBJECTIVE. The purpose of this study was to compare the image quality of anatomic images and iodine maps between high-pitch photon-counting detector (PCD) CTPA and dual-energy EID CTPA. METHODS. This prospective study included 117 patients (70 men and 47 women; median age, 65 years) who underwent CTPA to evaluate for pulmonary embolism between March 2022 and November 2022. Fifty-eight patients were randomized to undergo PCD CTPA (pitch, 2.0), and 59 were randomized to undergo EID CTPA (pitch, 0.55). For each examination, 120-kV polychromatic images, 60-keV virtual monogenetic images (VMIs), and iodine maps were reconstructed. One radiologist measured CNR and SNR. Three radiologists independently assessed subjective image quality (on a scale of 1-4, with a score of 1 denoting highest quality). Radiation dose was recorded. RESULTS. SNR and CNR were higher for PCD CTPA than for EID CTPA for polychromatic images and VMIs, for all assessed vessels other than the left upper lobe artery. For example, for PCD CTPA versus EID CTPA, the right lower lobe artery on polychromatic images had an SNR of 34.5 versus 28.0 (p = .003) and a CNR of 29.2 versus 24.4 (p = .001), and on VMIs it had an SNR of 43.2 versus 32.7 (p = .005) and a CNR of 37.4 versus 29.3 (p = .002). For both scanners for readers 1 and 2, the median image quality score for polychromatic images and VMIs was 1, although distributions indicated significantly better scores for PCD CTPA than for EID CTPA for polychromatic images for reader 1 (p = .02) and reader 2 (p = .005) and for VMIs for reader 1 (p = .001) and reader 2 (p = .006). The image quality of anatomic image sets was not different between PCD CTPA and EID CTPA for reader 3 (p > .05). The image quality of iodine maps was not different between PCD CTPA and EID CTPA for any reader (p > .05). For PCD CTPA versus EID CTPA, the CTDIvol was 3.9 versus 4.5 mGy (p = .03), and the DLP was 123.5 mGy × cm versus 157.0 mGy × cm (p < .001). CONCLUSION. High-pitch PCD CTPA provided anatomic images with better subjective and objective image quality versus dual-energy EID CTPA, with lower radiation dose. Iodine maps showed no significant difference in image quality between scanners. CLINICAL IMPACT. CTPA may benefit from the PCD CT technique.


Assuntos
Iodo , Masculino , Humanos , Feminino , Idoso , Estudos Prospectivos , Fótons , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Doses de Radiação
6.
Am J Nucl Med Mol Imaging ; 13(5): 208-216, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38023816

RESUMO

BACKGROUND: The aim of this study was to determine the read-out capabilities of the novel C-X-C motif chemokine receptor 4 (CXCR4)-targeting radiotracer [68Ga]Ga-PentixaFor compared to the reference radiotracer [18F]FDG in untreated individuals with head and neck squamous cell carcinoma (HNSCC). MATERIAL AND METHODS: 12 patients with histologically confirmed HNSCC were scheduled for [18F]FDG and [68Ga]Ga-PentixaFor PET/CT. Maximum standardized uptake values (SUVmax) and target-to-background ratios (TBR) were applied with vena cava superior serving as reference. In addition, we compared [68Ga]Ga-PentixaFor-PET findings with immunohistochemical (IHC) results of CXCR4 expression. RESULTS: On visual assessment, [18F]FDG identified more sites of disease, with increased detection rates for both the primary tumor ([18F]FDG, 12/12 [100%] vs. [68Ga]Ga-PentixaFor, 10/12 [83%]) and LN metastases ([18F]FDG, 9/12 [75%] vs. [68Ga]Ga-PentixaFor, 8/12 [67%]). Indicative for improved image contrast using [18F]FDG, quantification showed a higher TBR for the latter radiotracer, when compared to [68Ga]Ga-PentixaFor for all lesions ([18F]FDG, 11.7 ± 8.5 vs. [68Ga]Ga-PentixaFor, 4.3 ± 1.3; P=0.03), primary tumors ([18F]FDG, 13.6 ± 8.7 vs. [68Ga]Ga-PentixaFor, 4.4 ± 1.4; P<0.01), and LN lesions ([18F]FDG, 9.3 ± 10.6 vs. [68Ga]Ga-PentixaFor, 4.7 ± 1.5; P=0.3). IHC showed variable CXCR4 expression in the primary and LN, along with no associations between ex-vivo CXCR4 upregulation and [68Ga]Ga-PentixaFor-based TBR (R=0.33, P=0.39) or SUVmax (R=0.44, P=0.2). Of note, IHC also revealed heterogeneous expression of CXCR4 in immune cells in the tumor microenvironment and in germinal centers, indicative for inflammatory reactions. CONCLUSIONS: In HNSCC, [18F]FDG demonstrated superior diagnostic performance relative to [68Ga]Ga-PentixaFor, in particular for assessment of the primary. Based on the IHC analyses, these findings may be explained by CXCR4 upregulation not only by tumor but also by immune cells in the tumor microenvironment.

7.
Clin Nucl Med ; 48(11): 923-927, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37756444

RESUMO

BACKGROUND: Given their neuroendocrine origin, head and neck paragangliomas (HNPGLs) can be imaged with somatostatin receptor (SSTR)-directed PET/CT. We aimed to determine whether the in vivo PET signal can differentiate between varying HNPGL subtypes. PATIENTS AND METHODS: Fourteen patients with HNPGL received pretherapeutic SSTR-PET/CTs using 68 Ga-DOTATOC. Six (42.9%) patients had a jugular paraganglioma (PGL-J), 5 (35.7%) were diagnosed with carotid paraganglioma (PGL-Cs), and the remaining 3 patients (21.4%) had PGL-C with pathogenic SDHx germline variants (PGL-C-SDH). A visual and quantitative assessment of the primary tumor on SSTR-PET was performed, including SUV max and target-to-background ratio (TBR). Quantitative values were then compared between subgroups of patients affected with different HNPGL entities. RESULTS: On visual assessment, all primary HNPGLs could be identified on SSTR-PET/CT. Quantification of HNPGL revealed substantially elevated SUV max in PGL-J (101.7 ± 58.5) when compared with PGL-C-SDH (13.4 ± 5.6, P < 0.05), but not when compared with PGL-C (66.7 ± 27.3, P = 0.4; PGL-C vs PGL-C-SDH, P = 0.2). TBR of PGL-J (202.9 ± 82.2), however, further differentiated between PGL-C (95.7 ± 45.4, P < 0.05) and PGL-C-SDH (20.4 ± 12.2, P < 0.01; PGL-C vs PGL-C-SDH, P = 0.3). Moreover, whole-body readout revealed metastases in 2/3 (66.7%) of PGL-C-SDH patients, with a single SSTR-expressing skeletal lesion in one subject and bipulmonary lesions in the other patient. CONCLUSIONS: In patients with HNPGL, SSTR-PET/CT identified the primary and metastatic disease and provides substantially elevated TBR, indicating excellent image contrast. PET-based quantification can also differentiate between varying HNPGL subtypes.


Assuntos
Neoplasias de Cabeça e Pescoço , Paraganglioma Extrassuprarrenal , Paraganglioma , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Receptores de Somatostatina , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Paraganglioma Extrassuprarrenal/patologia , Paraganglioma/diagnóstico por imagem
8.
Nuklearmedizin ; 62(4): 229-234, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37666267

RESUMO

BACKGROUND: Despite anti-inflammatory treatment, patients with giant cell arteritis (GCA) experience relapse. We aimed to determine respective relapse predictors focusing on [18F]fluorodeoxyglucose ([18F]FDG)-PET-based parameters. MATERIAL AND METHODS: 21 therapy-naïve GCA patients received [18F]FDG-PET/CT. Patients were divided in two groups: those who relapsed during course of disease and those who did not. Median follow up was 15 months. [18F]FDG-PET/CT was analyzed for visual (PET vascular activity score [VAS]) and quantitative parameters, including Target-to-background-Ratio with liver (TBRliver) and jugular vein (TBRjv) serving as reference tissues. In addition, clinical parameters were tested. RESULTS: 8/21 (38.1 %) had relapse. Clinical parameters could not significantly discriminate between relapse vs no-relapse, including age (p = 0.9) or blood-based inflammatory markers (white blood cell counts [WBC] and c-reactive protein [CRP], p = 0.72, each). PETVAS score could also not differentiate between respective subgroups (p = 0.59). In a quantitative assessment, TBRjv demonstrated a trend towards significance (p = 0.28). TBRliver, however, separated between patients with and without relapse (p = 0.03). CONCLUSION: [18F]FDG PET quantification of vessels may be useful to identify GCA patients prone to relapse during follow-up.


Assuntos
Arterite de Células Gigantes , Humanos , Arterite de Células Gigantes/diagnóstico por imagem , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Inflamação/diagnóstico por imagem , Fígado , Doença Crônica
9.
Z Med Phys ; 2023 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-37684119

RESUMO

INTRODUCTION: Deep learning-based approaches are increasingly being used for the reconstruction of accelerated MRI scans. However, presented analyses are frequently lacking in-detail evaluation of basal measures like resolution or signal-to-noise ratio. To help closing this gap, spatially resolved maps of image resolution and noise enhancement (g-factor) are determined and assessed for typical model- and data-driven MR reconstruction methods in this paper. METHODS: MR data from a routine brain scan of a patient were undersampled in retrospect at R = 4 and reconstructed using two data-driven (variational network (VN), U-Net) and two model based reconstructions methods (GRAPPA, TV-constrained compressed sensing). Local resolution was estimated by the width of the main-lobe of a local point-spread function, which was determined for every single pixel by reconstructing images with an additional small perturbation. G-factor maps were determined using a multiple replica method. RESULTS: GRAPPA showed good spatial resolution, but increased g-factors (1.43-1.84, 75% quartile) over all other methods. The images delivered from compressed sensing suffered most from low local resolution, in particular in homogeneous areas of the image. VN and U-Net show similar resolution with mostly moderate local blurring, slightly better for U-Net. For all methods except GRAPPA the resolution as well as the g-factors depend on the anatomy and the direction of undersampling. CONCLUSION: Objective image quality parameters, local resolution and g-factors have been determined. The examined data driven methods show less local blurring than compressed sensing. The noise enhancement for reconstructions using CS, VN and U-Net is elevated at anatomical contours but is drastically reduced with respect to GRAPPA. Overall, the applied framework provides the possibility for more detailed analysis of novel reconstruction approaches incorporating non-linear and non-stationary transformations.

10.
Ann Rheum Dis ; 2023 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-37550004

RESUMO

OBJECTIVES: To update the EULAR recommendations for the use of imaging modalities in primary large vessel vasculitis (LVV). METHODS: A systematic literature review update was performed to retrieve new evidence on ultrasound, MRI, CT and [18F]-fluorodeoxyglucose positron emission tomography (FDG-PET) for diagnosis, monitoring and outcome prediction in LVV. The task force consisted of 24 physicians, health professionals and patients from 14 countries. The recommendations were updated based on evidence and expert opinion, iterating until voting indicated consensus. The level of agreement was determined by anonymous votes. RESULTS: Three overarching principles and eight recommendations were agreed. Compared to the 2018 version, ultrasound is now recommended as first-line imaging test in all patients with suspected giant cell arteritis, and axillary arteries should be included in the standard examination. As an alternative to ultrasound, cranial and extracranial arteries can be examined by FDG-PET or MRI. For Takayasu arteritis, MRI is the preferred imaging modality; FDG-PET, CT or ultrasound are alternatives. Although imaging is not routinely recommended for follow-up, ultrasound, FDG-PET or MRI may be used for assessing vessel abnormalities in LVV patients with suspected relapse, particularly when laboratory markers of inflammation are unreliable. MR-angiography, CT-angiography or ultrasound may be used for long-term monitoring of structural damage, particularly at sites of preceding vascular inflammation. CONCLUSIONS: The 2023 EULAR recommendations provide up-to-date guidance for the role of imaging in the diagnosis and assessment of patients with LVV.

11.
J Nucl Med ; 64(8): 1272-1278, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37290794

RESUMO

In patients with prostate cancer scheduled for systemic treatment, being overweight is linked to prolonged overall survival (OS), whereas sarcopenia is associated with shorter OS. We investigated fat-related and body composition parameters in patients undergoing prostate-specific membrane antigen (PSMA)-directed radioligand therapy (RLT) to assess their predictive value for OS. Methods: Body mass index (BMI, in kg/m2) and CT-derived body composition parameters (total, subcutaneous, visceral fat area, and psoas muscle area at the L3-L4 level) were determined for 171 patients scheduled for PSMA-directed RLT. After normalization for stature, the psoas muscle index was used to define sarcopenia. Outcome analysis was performed using Kaplan-Meier curves and Cox regression including fat-related and other clinical parameters (Gleason score, C-reactive protein [CRP], lactate dehydrogenase [LDH], hemoglobin, and prostate-specific antigen levels). The Harrell C-index was used for goodness-of-fit analysis. Results: Sixty-five patients (38%) had sarcopenia, and 98 patients (57.3%) had increased BMI. Relative to the 8-mo OS in normal-weight men (BMI < 25), overweight men (25 ≥ BMI > 30) and obese men (BMI ≥ 30) achieved a longer OS of 14 mo (hazard ratio [HR], 0.63; 95% CI, 0.40-0.99; P = 0.03) and 13 mo (HR, 0.47; 95% CI, 0.29-0.77; P = 0.004), respectively. Sarcopenia showed no impact on OS (11 vs. 12 mo; HR, 1.4; 95% CI, 0.91-2.1; P = 0.09). Most of the body composition parameters were tightly linked to OS on univariable analyses, with the highest C-index for BMI. In multivariable analysis, a higher BMI (HR, 0.91; 95% CI, 0.86-0.97; P = 0.006), lower CRP (HR, 1.09; 95% CI, 1.03-1.14; P < 0.001), lower LDH (HR, 1.08; 95% CI, 1.03-1.14; P < 0.001), and longer interval between initial diagnosis and RLT (HR, 0.95; 95% CI, 0.91-0.99; P = 0.02) were significant predictors of OS. Conclusion: Increased fat reserves assessed by BMI, CRP, LDH, and interval between initial diagnosis and RLT, but not CT-derived body composition parameters, were relevant predictors for OS. As BMI can be altered, future research should investigate whether a high-calorie diet before or during PSMA RLT may improve OS.


Assuntos
Neoplasias de Próstata Resistentes à Castração , Sarcopenia , Masculino , Humanos , Índice de Massa Corporal , Neoplasias de Próstata Resistentes à Castração/radioterapia , Neoplasias de Próstata Resistentes à Castração/complicações , Sarcopenia/induzido quimicamente , Sarcopenia/complicações , Sarcopenia/tratamento farmacológico , Antígeno Prostático Específico/metabolismo , Sobrepeso/induzido quimicamente , Sobrepeso/complicações , Sobrepeso/tratamento farmacológico , Próstata/metabolismo , Resultado do Tratamento , Lutécio/uso terapêutico , Estudos Retrospectivos , Compostos Heterocíclicos com 1 Anel/uso terapêutico , Dipeptídeos/uso terapêutico
12.
Eur Radiol ; 33(11): 7830-7839, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37311805

RESUMO

OBJECTIVE: To evaluate the image quality of an ultra-low contrast medium and radiation dose CT pulmonary angiography (CTPA) protocol for the diagnosis of acute pulmonary embolism using a clinical photon-counting detector (PCD) CT system and compare its performance to a dual-energy-(DE)-CTPA protocol on a conventional energy-integrating detector (EID) CT system. METHODS: Sixty-four patients either underwent CTPA with the novel scan protocol on the PCD-CT scanner (32 patients, 25 mL, CTDIvol 2.5 mGy·cm) or conventional DE-CTPA on a third-generation dual-source EID-CT (32 patients, 50 mL, CTDIvol 5.1 mGy·cm). Pulmonary artery CT attenuation, signal-to-noise ratio, and contrast-to-noise-ratio were assessed as objective criteria of image quality, while subjective ratings of four radiologists were compared at 60 keV using virtual monoenergetic imaging and polychromatic standard reconstructions. Interrater reliability was determined by means of the intraclass correlation coefficient (ICC). Effective dose was compared between patient cohorts. RESULTS: Subjective image quality was deemed superior by all four reviewers for 60-keV PCD scans (excellent or good ratings in 93.8% of PCD vs. 84.4% of 60 keV EID scans, ICC = 0.72). No examinations on either system were considered "non-diagnostic." Objective image quality parameters were significantly higher in the EID group (mostly p < 0.001), both in the polychromatic reconstructions and at 60 keV. The ED (1.4 vs. 3.3 mSv) was significantly lower in the PCD cohort (p < 0.001). CONCLUSIONS: PCD-CTPA allows for considerable reduction of contrast medium and radiation dose in the diagnosis of acute pulmonary embolism, while maintaining good to excellent image quality compared to conventional EID-CTPA. CLINICAL RELEVANCE STATEMENT: Clinical PCD-CT allows for spectral assessment of pulmonary vasculature with high scan speed, which is beneficial in patients with suspected pulmonary embolism, frequently presenting with dyspnea. Simultaneously PCD-CT enables substantial reduction of contrast medium and radiation dose. KEY POINTS: • The clinical photon-counting detector CT scanner used in this study allows for high-pitch multi-energy acquisitions. • Photon-counting computed tomography allows for considerable reduction of contrast medium and radiation dose in the diagnosis of acute pulmonary embolism. • Subjective image quality was rated best for 60-keV photon-counting scans.


Assuntos
Redução da Medicação , Embolia Pulmonar , Humanos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos , Embolia Pulmonar/diagnóstico por imagem , Artéria Pulmonar/diagnóstico por imagem , Fótons , Imagens de Fantasmas
13.
Cancers (Basel) ; 15(10)2023 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-37345187

RESUMO

OBJECTIVES: Positron emission tomography (PET) is currently considered the non-invasive reference standard for lymph node (N-)staging in lung cancer. However, not all patients can undergo this diagnostic procedure due to high costs, limited availability, and additional radiation exposure. The purpose of this study was to predict the PET result from traditional contrast-enhanced computed tomography (CT) and to test different feature extraction strategies. METHODS: In this study, 100 lung cancer patients underwent a contrast-enhanced 18F-fluorodeoxyglucose (FDG) PET/CT scan between August 2012 and December 2019. We trained machine learning models to predict FDG uptake in the subsequent PET scan. Model inputs were composed of (i) traditional "hand-crafted" radiomics features from the segmented lymph nodes, (ii) deep features derived from a pretrained EfficientNet-CNN, and (iii) a hybrid approach combining (i) and (ii). RESULTS: In total, 2734 lymph nodes [555 (20.3%) PET-positive] from 100 patients [49% female; mean age 65, SD: 14] with lung cancer (60% adenocarcinoma, 21% plate epithelial carcinoma, 8% small-cell lung cancer) were included in this study. The area under the receiver operating characteristic curve (AUC) ranged from 0.79 to 0.87, and the scaled Brier score (SBS) ranged from 16 to 36%. The random forest model (iii) yielded the best results [AUC 0.871 (0.865-0.878), SBS 35.8 (34.2-37.2)] and had significantly higher model performance than both approaches alone (AUC: p < 0.001, z = 8.8 and z = 22.4; SBS: p < 0.001, z = 11.4 and z = 26.6, against (i) and (ii), respectively). CONCLUSION: Both traditional radiomics features and transfer-learning deep radiomics features provide relevant and complementary information for non-invasive N-staging in lung cancer.

14.
Eur Radiol ; 33(11): 7913-7922, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37256352

RESUMO

OBJECTIVES: We conducted a systematic review and individual participant data meta-analysis of publications reporting the ophthalmologic presentation, clinical exam, and orbital MRI findings in patients with giant cell arteritis and ocular manifestations. METHODS: PubMed and Cochrane databases were searched up to January 16, 2022. Publications reporting patient-level data on patients with ophthalmologic symptoms, imaged with orbital MRI, and diagnosed with biopsy-proven giant cell arteritis were included. Demographics, clinical symptoms, exam, lab, imaging, and outcomes data were extracted. The methodological quality and completeness of reporting of case reports were assessed. RESULTS: Thirty-two studies were included comprising 51 patients (females = 24; median age, 76 years). Vision loss (78%) and headache (45%) were commonly reported visual and cranial symptoms. Ophthalmologic presentation was unilateral (41%) or bilateral (59%). Fundus examination most commonly showed disc edema (64%) and pallor (49%). Average visual acuity was very poor (2.28 logMAR ± 2.18). Diagnoses included anterior (61%) and posterior (16%) ischemic optic neuropathy, central retinal artery occlusion (8%), and orbital infarction syndrome (2%). On MRI, enhancement of the optic nerve sheath (53%), intraconal fat (25%), and optic nerve/chiasm (14%) was most prevalent. Among patients with monocular visual symptoms, 38% showed pathologic enhancement in the asymptomatic orbit. Six of seven cases reported imaging resolution after treatment on follow-up MRIs. CONCLUSIONS: Vision loss, pallid disc edema, and optic nerve sheath enhancement are the most common clinical, fundoscopic, and imaging findings reported in patients diagnosed with giant cell arteritis with ocular manifestations, respectively. MRI may detect subclinical inflammation and ischemia in the asymptomatic eye and may be an adjunct diagnostic tool. CLINICAL RELEVANCE STATEMENT: Brain and orbital MRIs may have diagnostic and prognostic roles in patients with suspected giant cell arteritis who present with ophthalmic symptoms.


Assuntos
Arterite de Células Gigantes , Neuropatia Óptica Isquêmica , Feminino , Humanos , Idoso , Arterite de Células Gigantes/complicações , Arterite de Células Gigantes/diagnóstico por imagem , Transtornos da Visão , Imageamento por Ressonância Magnética/métodos , Neuropatia Óptica Isquêmica/diagnóstico , Neuropatia Óptica Isquêmica/etiologia , Edema/complicações
15.
Eur Radiol ; 33(4): 2529-2535, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36394601

RESUMO

OBJECTIVE: Blindness is a feared complication of giant cell arteritis (GCA). However, the spectrum of pathologic orbital imaging findings on magnetic resonance imaging (MRI) in GCA is not well understood. In this study, we assess inflammatory changes of intraorbital structures on black blood MRI (BB-MRI) in patients with GCA compared to age-matched controls. METHODS: In this multicenter case-control study, 106 subjects underwent BB-MRI. Fifty-six patients with clinically or histologically diagnosed GCA and 50 age-matched controls without clinical or laboratory evidence of vasculitis were included. All individuals were imaged on a 3-T MR scanner with a post-contrast compressed-sensing (CS) T1-weighted sampling perfection with application-optimized contrasts using different flip angle evolution (SPACE) BB-MRI sequence. Imaging results were correlated with available clinical symptoms. RESULTS: Eighteen of 56 GCA patients (32%) showed inflammatory changes of at least one of the intraorbital structures. The most common finding was enhancement of at least one of the optic nerve sheaths (N = 13, 72%). Vessel wall enhancement of the ophthalmic artery was unilateral in 8 and bilateral in 3 patients. Enhancement of the optic nerve was observed in one patient. There was no significant correlation between imaging features of inflammation and clinically reported orbital symptoms (p = 0.10). None of the age-matched control patients showed any inflammatory changes of intraorbital structures. CONCLUSIONS: BB-MRI revealed inflammatory findings in the orbits in up to 32% of patients with GCA. Optic nerve sheath enhancement was the most common intraorbital inflammatory change on BB-MRI. MRI findings were independent of clinically reported orbital symptoms. KEY POINTS: • Up to 32% of GCA patients shows signs of inflammation of intraorbital structures on BB-MRI. • Enhancement of the optic nerve sheath is the most common intraorbital finding in GCA patients on BB-MRI. • Features of inflammation of intraorbital structures are independent of clinically reported symptoms.


Assuntos
Arterite de Células Gigantes , Humanos , Arterite de Células Gigantes/complicações , Arterite de Células Gigantes/diagnóstico por imagem , Estudos de Casos e Controles , Angiografia por Ressonância Magnética , Imageamento por Ressonância Magnética/métodos , Inflamação/patologia , Artérias Temporais/patologia
16.
Acad Radiol ; 30(7): 1358-1366, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36167629

RESUMO

OBJECTIVES: Gantry-free cone-beam CT (CBCT) allows for comfortable patient positioning due to an open scanner architecture. Since CBCT without gantry is not yet established for clinical wrist trauma imaging, this study's aim was to investigate its diagnostic value in the preoperative workup of patients with distal radius and scaphoid fractures. METHODS: Within a 12-month period, 113 patients with severe wrist trauma underwent both radiography and CBCT with the same gantry-free multi-use scanner before surgery. Two radiologists retrospectively analyzed all datasets for the morphology of distal radius (n = 95) and scaphoid fractures (n = 20). In all 115 wrists (two bilateral injuries), surgical reports served as the standard of reference. RESULTS: While accuracy for distal radius fractures was comparable among CBCT and radiographs, the former was superior with regard to scaphoid fractures (Reader 1: 100.0% vs. 75.0%; Reader 2: 100.0% vs. 65.0%). Accuracy for multi-fragmentary radius injuries (100.0% vs. 90.5%; 100.0% vs. 93.7%), and articular affliction (99.0% vs. 84.2%; 100.0% vs. 83.2%) was also higher in CBCT. Regarding scaphoid fractures, CBCT proved superior for diagnosis of proximal pole or waist involvement (100.0% vs. 70.0%; 100.0% vs. 65.0%) and comminuted patterns (100.0% vs. 70.0%; 100.0% vs. 75.0%). Median effective dose of CBCT was as low as 3.65 µSv compared with 0.16 µSv for standard radiography. CONCLUSION: Gantry-free CBCT allows for excellent diagnostic accuracy in the assessment of distal radius and scaphoid fracture morphology. Even in patients with limited mobility, very low radiation dose is sufficient to maintain high image quality.


Assuntos
Fraturas Ósseas , Osso Escafoide , Humanos , Fraturas Ósseas/diagnóstico por imagem , Rádio (Anatomia) , Estudos Retrospectivos , Osso Escafoide/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico
17.
Nuklearmedizin ; 61(6): 425-432, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35977673

RESUMO

OBJECTIVES: 2-deoxy-2-[18F]fluoro-D-glucose ([18F]FDG) PET/CT can be utilized in patients with giant cell arteritis (GCA), but pretest probability of established laboratory marker such as C-reactive protein (CRP) and white blood cell count (WBC) has not been defined yet. We aimed to elucidate the clinical utility of CRP and WBC for scheduling an [18F]FDG scan. METHODS: 18 treatment-naïve GCA patients and 14 GCA subjects with anti-inflammatory treatment (glucocorticoids or comparable drugs), who underwent [18F]FDG PET/CT and who had no other inflammatory disease at time of scan, were identified. A semi-quantitative analysis in 11 vessel segments was conducted, with averaged jugular vein, healthy liver and lung tissue (Target-to-background ratio [TBR]VJ/liver/lung) serving as background. Derived TBR were then correlated with CRP and WBC at time of PET using Spearman's correlation. RESULTS: For all treatment-naïve patients, TBRVJ was 2.3±1.1 (95%CI, 2.2-2.5), TBRliver was 1.0±0.5 (95%CI, 0.9-1.0) and average TBRlung was 6.3±3.6 (95%CI, 5.8-6.8). No significant correlation was noted for either CRP (TBRVJ: R=-0.19; TBRliver: R=-0.03; TBRlung: R=-0.17; each P ≥ 0.44) or for WBC (TBRVJ: R=-0.40; TBRliver: R=-0.32; TBRlung: R=-0.37; each P ≥ 0.10). Similar results were recorded for patients under treatment at time of PET. Again, no significant correlation was reached for either CRP (TBRVJ: R=-0.17; TBRliver: R=-0.28; TBRlung: R=-0.09; each P ≥ 0.32) or WBC (TBRVJ: R=-0.06; TBRliver: R=-0.13; TBRlung: R=0.06; each P ≥ 0.65). CONCLUSIONS: In GCA patients with and without anti-inflammatory treatment, CRP and WBC did not substantially correlate with TBR at time of scan. Given the rather limited pretest probability of those parameters, such laboratory values may have less diagnostic utility to order an [18F]FDG PET/CT.


Assuntos
Arterite de Células Gigantes , Humanos , Arterite de Células Gigantes/diagnóstico por imagem , Fluordesoxiglucose F18/uso terapêutico , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Proteína C-Reativa , Contagem de Leucócitos
18.
Magn Reson Med ; 88(5): 2167-2178, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35692042

RESUMO

PURPOSE: Cardiac MRI represents the gold standard to determine myocardial function. However, the current clinical standard protocol, a segmented Cartesian acquisition, is time-consuming and can lead to compromised image quality in the case of arrhythmia or dyspnea. In this article, a machine learning-based reconstruction of undersampled spiral k-space data is presented to enable free breathing real-time cardiac MRI with good image quality and short reconstruction times. METHODS: Data were acquired in free breathing with a 2D spiral trajectory corrected by the gradient system transfer function. Undersampled data were reconstructed by a variational network (VN), which was specifically adapted to the non-Cartesian sampling pattern. The network was trained with data from 11 subjects. Subsequently, the imaging technique was validated in 14 subjects by quantifying the difference to a segmented reference acquisition, an expert reader study, and by comparing derived volumes and functional parameters with values obtained using the current clinical gold standard. RESULTS: The scan time for the entire heart was below 1 min. The VN reconstructed data in about 0.9 s per image, which is considerably shorter than conventional model-based approaches. The VN furthermore performed better than a U-Net and not inferior to a low-rank plus sparse model in terms of achieved image quality. Functional parameters agreed, on average, with reference data. CONCLUSIONS: The proposed VN method enables real-time cardiac imaging with both high spatial and temporal resolution in free breathing and with short reconstruction time.


Assuntos
Imageamento por Ressonância Magnética , Respiração , Coração/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Cintilografia
19.
PLoS One ; 17(6): e0270689, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35767553

RESUMO

BACKGROUND: To investigate the effects of B1-shimming and radiofrequency (RF) parallel transmission (pTX) on the visualization and quantification of the degree of stenosis in a coronary artery phantom using 7 Tesla (7 T) magnetic resonance imaging (MRI). METHODS: Stenosis phantoms with different grades of stenosis (0%, 20%, 40%, 60%, 80%, and 100%; 5 mm inner vessel diameter) were produced using 3D printing (clear resin). Phantoms were imaged with four different concentrations of diluted Gd-DOTA representing established arterial concentrations after intravenous injection in humans. Samples were centrally positioned in a thorax phantom of 30 cm diameter filled with a custom-made liquid featuring dielectric properties of muscle tissue. MRI was performed on a 7 T whole-body system. 2D-gradient-echo sequences were acquired with an 8-channel transmit 16-channel receive (8 Tx / 16 Rx) cardiac array prototype coil with and without pTX mode. Measurements were compared to those obtained with identical scan parameters using a commercially available 1 Tx / 16 Rx single transmit coil (sTX). To assess reproducibility, measurements (n = 15) were repeated at different horizontal angles with respect to the B0-field. RESULTS: B1-shimming and pTX markedly improved flip angle homogeneity across the thorax phantom yielding a distinctly increased signal-to-noise ratio (SNR) averaged over a whole slice relative to non-manipulated RF fields. Images without B1-shimming showed shading artifacts due to local B1+-field inhomogeneities, which hampered stenosis quantification in severe cases. In contrast, B1-shimming and pTX provided superior image homogeneity. Compared with a conventional sTX coil higher grade stenoses (60% and 80%) were graded significantly (p<0.01) more precise. Mild to moderate grade stenoses did not show significant differences. Overall, SNR was distinctly higher with B1-shimming and pTX than with the conventional sTX coil (inside the stenosis phantoms 14%, outside the phantoms 32%). Both full and half concentration (10.2 mM and 5.1 mM) of a conventional Gd-DOTA dose for humans were equally suitable for stenosis evaluation in this phantom study. CONCLUSIONS: B1-shimming and pTX at 7 T can distinctly improve image homogeneity and therefore provide considerably more accurate MR image analysis, which is beneficial for imaging of small vessel structures.


Assuntos
Vasos Coronários , Ondas de Rádio , Constrição Patológica , Vasos Coronários/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes
20.
NMR Biomed ; 35(8): e4732, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35297111

RESUMO

The purpose of the current study was to implement and validate joint real-time acquisition of functional and late gadolinium-enhancement (LGE) cardiac magnetic resonance (MR) images during free breathing. Inversion recovery cardiac real-time images with a temporal resolution of 50 ms were acquired using a spiral trajectory (IR-CRISPI) with a pre-emphasis based on the gradient system transfer function during free breathing. Functional and LGE cardiac MR images were reconstructed using a low-rank plus sparse model. Late gadolinium-enhancement appearance, image quality, and functional parameters of IR-CRISPI were compared with clinical standard balanced steady-state free precession breath-hold techniques in 10 patients. The acquisition of IR-CRISPI in free breathing of the entire left ventricle took 97 s on average. Bland-Altman analysis and Wilcoxon tests showed a higher artifact level for the breath-hold technique (p = 0.003), especially for arrhythmic patients or patients with dyspnea, but an increased noise level for IR-CRISPI of the LGE images (p = 0.01). The estimated transmural extent of the enhancement differed by not more than 25% and did not show a significant bias between the techniques (p = 0.50). The ascertained functional parameters were similar for the breath-hold technique and IR-CRISPI, that is, with a minor, nonsignificant (p = 0.16) mean difference of the ejection fraction of 2.3% and a 95% confidence interval from -4.8% to 9.4%. IR-CRISPI enables joint functional and LGE imaging in free breathing with good image quality but distinctly shorter scan times in comparison with breath-hold techniques.


Assuntos
Meios de Contraste , Gadolínio , Suspensão da Respiração , Coração/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética/métodos , Imagem Cinética por Ressonância Magnética/métodos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA